Some protocols and the states of the coding switches of normal baud rates of these protocols
are shown as follows:
NEON/ 9600Bps
ON
1234 56
PELCO- D/ 2400Bps
ON
1234 56
PELCO- P/ 4800Bps
ON
1234 56
PELCO- P/ 9600Bps
ON
1234 56
PANASONI C/ 9600Bps
ON
1 234 56
KALATEL/ 4800Bps
ON
1 234 56
Ul t r ak/ 9600Bps
ON
1 234 56
ALEC/ 9600Bps
ON
1 234 56
Setup of the Baud Rate of Communication.
As shown in Figure 2, SW2 is used to set the protocol of communication and the baud rate used by the dome
camera. DIP-6 and DIP-5 of SW2 are used to select the baud rate of communication and 4 different baud rates can
be selected in maximum. If the controller adopts a non-standard baud rate, you can adjust it to be identical with
that of the controller, as per the following table.
Setup of Baud Rate
Baud Rate of Communication DIP-1 DIP-2 DIP-3 DIP-4
DIP-5 DIP-6
2400bps OFF OFF
4800bps ON OFF
9600bps OFF ON
19200bps ON ON
B01 9600Bps
PELCO-P/D 2400Bps
ON
1
2
3
4
PELCO-P/D 4800Bps
PELCO-MK 4800 BPS